Get Huawei H19-338 Dumps Questions [2021] To Gain Brilliant Result [Q80-Q104]

Share

Get Huawei H19-338 Dumps Questions [2021] To Gain Brilliant Result

H19-338 dumps - Prep4sureGuide - 100% Passing Guarantee

NEW QUESTION 80
Which of the following statements about LUN mapping on Dorado V6 is incorrect?

  • A. New LUN groups can be directly mapped to a host.
  • B. A mapping view must be created.
  • C. LUNs or LUN groups can be created on the host mapping page
  • D. New LUNS can be directly mapped to a host or added to a LUN group (which has been mapped to a host)

Answer: D

 

NEW QUESTION 81
Which technique is used to protect end-to-end data integrity?

  • A. DIX+T10
  • B. SHA
  • C. CRC

Answer: A

 

NEW QUESTION 82
Which is the protocol for networking a smart disk enclosure with controller enclosures?

  • A. SAS
  • B. FC
  • C. PCIe
  • D. 100GE RoCE

Answer: D

 

NEW QUESTION 83
Which of the following is not a VDI application scenario in the healthcare industry?

  • A. Telemedicine assistance and training
  • B. Public terminal
  • C. Patient information and management system
  • D. Surgical treatment room

Answer: D

 

NEW QUESTION 84
The active-active status will be interrupted if a quorum server is faulty.

  • A. False
  • B. True

Answer: A

 

NEW QUESTION 85
Which statements about HyperMetro (Active-Active) supports by Dorado are correct? (Multiple Choice)

  • A. Gateway-free
  • B. Online upgrade from the HyperMetro solution to the 3DC solution
  • C. Online upgrade from a single DC to dual-DC HyperMetro

Answer: A,B,C

 

NEW QUESTION 86
Which of the following specifications is correct for NVMe disk enclosures (Intellegent DAE)?

  • A. 36 disks per 1U
  • B. 25 disks per 2U
  • C. 25 disks per 1U
  • D. 36 disks per 2U

Answer: D

 

NEW QUESTION 87
Two quorum devices are deployed at the third-place site.
Both quorum devices can be used for arbitration at the same time.

  • A. False
  • B. True

Answer: A

 

NEW QUESTION 88
Which software architecture does the OceanStor V5 use?

  • A. FS-based block architecture
  • B. Parallel block and FS architecture
  • C. Block-based FS architecutre

Answer: B

 

NEW QUESTION 89
Which statement about the DR star for OceanStor V5 is true? (Multiple choice)

  • A. Active-active + asynchronous replication + asynchronous replication (standby).
  • B. Synchronous + asynchronous replication + asynchronous replication (standby)
  • C. Asynchronous replication + asynchronous replication + asynchronous replication (standby)

Answer: A,B

 

NEW QUESTION 90
In static-priority arbitration mode, if the active-active relationships are functional, but all replication links between storage arrays are down, what will happen?

  • A. Services stop at the preferred site while they continue at the non-preferred site
  • B. Services continues at the preferred site while they stop at the non-preferred site
  • C. Services stop at both the preferred and non-preferred sites
  • D. Services continues at both the preferred and non-preferred sites

Answer: B

 

NEW QUESTION 91
In static-priority arbitration mode, if the active-active relationships are functioning, but all replication links between storage arrays are down.
What will happen?

  • A. Services continue at the preferred site while they stop at the non-preferred site
  • B. Service continues at both the preferred and non-preferred sites
  • C. Services stop at the preferred-site while they continue at the non-preferred site
  • D. Service stop at both the preferred and non-preferred sites

Answer: A

 

NEW QUESTION 92
Which are the key technologies of SmartMatrix 3.0? (Multiple Choice)

  • A. Continuous cache mirroring
  • B. iSCSI and NAS FIM
  • C. Back-end Interconnect I/O Module (BIM)
  • D. FC Front-end Interconnect I/O Module (FC FIM)

Answer: A,C,D

 

NEW QUESTION 93
Which technologies are used to improve Dorado performance? (Multiple choice)

  • A. I/O priority scheduling policy that assigns different priorities for different types of I/Os.
  • B. RAID-IP
  • C. CPU grouping algorithm that uses dedicated cores for I/O reads and writes.
  • D. Full-strip write
  • E. Wear leveling and anti-wear leveling technologies.

Answer: A,C,D

 

NEW QUESTION 94
Dorado V3 (same with Dorado V6) supports three kinds of RAID types _____, and the default RAID type is ______, while _____ supports triple disk failure.

  • A. RAID-5/RAID-6/RAID-10; RAID-5; RAID-10
  • B. RAID-5/RAID-6/RAID-TP; RAID-5; RAID-TP
  • C. RAID-5/RAID-6/RAID-TP; RAID-6; RAID-TP

Answer: C

 

NEW QUESTION 95
Which reliability technologies are used in Huawei all-flash storage? (Multiple choice)

  • A. Wear leveling
  • B. RAID
  • C. Power failure protection
  • D. Bad block management

Answer: A,B,D

 

NEW QUESTION 96
OceanStor 100D provides inline deduplication.

  • A. True
  • B. False

Answer: A

 

NEW QUESTION 97
When only one LUN is configured in a Dorado V6 system, how many controllers are involved in the process?

  • A. 0
  • B. 1
  • C. All controllers online
  • D. 2

Answer: C

 

NEW QUESTION 98
The deduplication and compression ratio of each LUN can be viewed on the DeviceManager of Dorado V3 (same with Dorado VG)

  • A. True
  • B. False

Answer: A

 

NEW QUESTION 99
RAID2.0+ is a block-based virtualization technology. Disks are divided into CKs and CKGs form RAID groups. Therefore, compared with traditional RAID, RAID2.0+ does not require hot spare disks or hot spare space.

  • A. False
  • B. True

Answer: A

 

NEW QUESTION 100
HyperCDP objects can be used to restore data but cannot be directly mapped to hosts for read and write operations.

  • A. False
  • B. True

Answer: A

 

NEW QUESTION 101
Dorado V6 supports both scale-out and scale-up.

  • A. True
  • B. False

Answer: A

 

NEW QUESTION 102
Which are the convergence technologies that OceanStor V5 converged storage support? (Multiple choice)

  • A. Convergence of storage resource pools: resource pooling and interruption free heterogeneous migration.
  • B. Convergence of flash storage: interconnection between different types, models, and generations.
  • C. Active-active convergencE: HyperMetro for SAN and NAS, RPO=0, RTO=0.
  • D. Convergence of SAN and NAS: HyperMetro for SAN and NAS, multi-service integration.
  • E. Cloud convergence: hybrid cloud interoperability, along with public cloud migration, backup, and DR.

Answer: A,B,C,D

 

NEW QUESTION 103
What is the minimum activation interval supported by HyperCDP of Dorado V6?

  • A. 3s
  • B. 5s
  • C. 30s
  • D. 10s

Answer: A

 

NEW QUESTION 104
......

Get 100% Passing Success With True H19-338 Exam: https://www.prep4sureguide.com/H19-338-prep4sure-exam-guide.html

Premium Quality Huawei H19-338 Online dumps: https://drive.google.com/open?id=13CLK__KgGzRZy6tEqWYW0v4yGdTKuegr